What is APC Easy UPS SRV 1000VA 230V? At the lowest price MI Atlantic EU
APC Simple UPS
For IT specialists in small and medium-sized enterprises, APC Easy UPS Online delivers basic power defense for unbalanced power conditions,
ensuring reliable and reliable influences at the most critical moments. APC
Easy UPS Online is a multi-functional, high-quality, cost-competitive UPS
designed to handle wide voltage ranges and unpredictable power conditions; it
provides quality trusted by millions of IT professionals international.
Electrical Safety:
Do not handle any metal connectors before separating the
power source. For models with hard-wired inputs, a fit electrician must be
connected to the division circuit (power supply). 230 V models only: To comply
with the EMC instruction of products sold in Europe, the length of the output
cable linked to the UPS must not top 10 meters. The defensive earth conductor
of the UPS carries the escaping current from the load gear (computer
equipment). The cloistered grounding electrode will be installed as part of the
branch circuit that provisions the UPS.
The conductor size and lining material must be the same as
the beached and ungrounded branch power conductors. The electrode is usually
green, with or deprived of yellow bands. When a separate ground terminal is
used, the leakage current of the pluggable UPS type may exceed 3.5 mA. The UPS
input ground conductor must be appropriately connected to the protective ground
on the service panel. If the UPS input power is provided by a separately
derived system, the foundation conductor must be properly connected to the
power modifier or motor-generator set.
Power failure safety:
The UPS contains internal batteries. Even if the AC and DC
power sources are detached, there may be a risk of electric shock. The AC and
DC output connectors can be thrilled at any time through remote or involuntary
control. Before installing or servicing the tools, please check: The input
circuit breaker is in the OFF situation. The internal UPS battery has been detached.
The XLBP battery module is detached.
Battery safety:
The battery usually lasts two to five years. Environmental
factors affect battery life. Increased ambient temperature, poor utility power
quality, and frequent short-time discharges will shorten battery life. The
battery should be replaced before the end of its service life. When the device
indicates that the battery needs to be replaced, replace the battery
immediately. When replacing the batteries, replace them with the same number
and type of batteries as originally installed in the device.
Schneider Electric uses maintenance-free sealed lead-acid
batteries. Under normal use and treatment, there is no contact with the
internal gears of the battery. Overpricing, overheating, or another misuse of
the battery can cause the battery electrolyte to discharge. The released
electrolyte is toxic and may be harmful to the casing and eyes.
Warn
Before connecting or replacing the battery, remove jewelry
such as jewelry, watches, and rings. Use tools with shielded handles. High
short-circuit flows through conductive materials can cause severe burns. Do not
open or injury the battery. The released substance is damaging to the skin and
eyes and may be toxic.
General information:
·
The UPS will know up to 10 external battery
packs linked to the UPS.
·
The model and serial amount are located on a
small rear panel label. For some models, an extra label is situated under the
front bezel of the chassis.
·
Recycle wrapping materials or save them for
reuse.
·
Always recycle used batteries.
Hardware security:
• Check countrywide and local regulations before cabling.
• It needs to be wired by a qualified electrician.
• Choose wire size and connectors according to national and
local rules.
• Before connecting cables or making connections (whether in
the connection box or with the UPS), check that all division circuits (mains)
and low voltage (control) circuits are energized and protected.
• All hard wiring needs strain relief (supplied with select
products). It is optional to use a Snap-On strain relief device.
• All starts that allow access to the hard-wired stations of
the UPS must be covered. Otherwise, personal injury or equipment injury may
result.
System Requirements
• At least 200MB hard disk interplanetary
• Needs administrator rights
• At least 256 MB of bodily memory (512 MB optional)
• The TCP/IP protocol must be installed for network organization
• It is optional to use 16-bit or higher color and 800 x 600
or higher resolution monitor