Network power UPS
Your new Cyber Power UPS can be used as quickly as it is conventional.
However, it is optional to charge the battery for at least 8 hours to ensure
that the all-out charging capacity of the battery-operated is reached. Charge
loss may occur during transport and storage. To charge the cordless, simply
plug the expedient into an AC power opening. The device will charge in the on
and off-sites. This up is intended with a safety purpose to stop the system
from being opened during conveyance. When you turn on the UPS for the first
time, you need to attach it to AC power, then it will not be motor on. If you
will use the software, attach the USB cable to the USB port on the UPS.
Plugin the UPS
Plug the UPS into a 2-pole 3-wire beached socket (wall socket). Make sure that the branch holes on the wall are endangered by fuses or circuit breakers, and do not repair gear that requires a lot of power (such as air conditioners, refrigerators, duplicators, etc.). Avoid using postponement cords. Press the power switch to turn on the gear. The power-on pointer is on and the gear emits a “Honk" sound. If an overload is noticed, a perceptible alarm will sound and the device will emit a long beep. To precise, this situation, turn off the UPS and clear at least one device from a battery-powered opening.
Make sure that the circuit wave is pressed, and then turn on
the UPS. Your UPS is armed with an involuntary charging purpose. When the UPS
is worked into an AC power outlet, the battery will mechanically charge. To continue
the best battery power, always plug the UPS into an AC power outlet. To store
the UPS for a long time, cover it and store it with the battery fully charged.
Charge the battery every three months to safeguard battery life.
Battery replacement
Important safety instructions before repairing the battery.
Repair the battery under the management of a person who understands the battery
and its defenses. Use only the quantified type of battery. Please contact your
dealer to replace the battery-operated. There may be a risk of electric shock
from the battery. Do not throw series into the fire, as they may explode.
Observe all local principles regarding the proper discarding of batteries. Do
not open or damage the battery. The at-large electrolyte is harmful to the skin
and eyes and may be toxic. The battery may have a high risk of short-circuit existing
and electric shock.
• Do not place tools or other metal shares on top of the
battery or any battery terminals.
• Control if the battery is accidentally grounded. If you
accidentally ground the ground, remove the ground source.
• Only use tools with protected handles.
• Wear rubber gloves and boots.
Battery replacement procedure
• Turn off and unplug all associated devices.
• Turn off the UPS and clear it from the AC control source.
• Lay the UPS on its side.
• Remove the fixing screws situated on the lowest of the
UPS.
• Separate the battery wire from the battery.
• CP1300EPFCLCD: Install the added battery by connecting the
red wire (+) and black wire (-) to the connectors of the same hue in the
battery pack.
• Slide the battery section cover completely out of the
device
Light-emitting liquid crystal display
During a severe power letdown or power failure, this icon
will appear and a fear sound (two short beeps shadowed by a pause) will
indicate that the UPS is running on its interior battery. During a long power
outage or control outage, the alarm will beep rapidly every 1/2 additional and
the battery. The capacity meter shows a shadow of a 20% capacity segment. The volume
depends on the amount of load added and the remaining running time. To designate
that the UPS battery is nearly dead. You should directly save the file and shut
down the device or let the software shut down the organization.
Energy-saving:
The UPS is in energy-saving bypass mode. For more info,
please refer to the "Cyber Power Green Power UPS Technology" unit.
Load capacity/sensitivity setting:
This meter presents the estimated output load level of the
UPS cordless socket (in 20% increments). It can also be a kindliness setting
table if you use it to control the sympathy of UPS swapping to battery mode by choosing
the UPS closure voltage range. The higher the sensitivity, the easier it is for
the UPS to switch to cordless mode.